Search results for "Standard technique"
showing 9 items of 9 documents
Prevention of ischemic-type biliary lesions by arterial back-table pressure perfusion
2003
Abstract Ischemic-type biliary lesions (ITBLs) lead to considerable morbidity after orthotopic liver transplantation (OLT). The exact pathogenesis is unknown. We tested the hypothesis that insufficient perfusion of biliary arterial vessels might be responsible for ITBLs. This could be prevented by improved perfusion techniques. Since February 2000, we performed a controlled study using arterial back-table pressure perfusion (AP) to achieve reliable perfusion of the biliary-tract capillary system, which may be impaired by the high viscosity of University of Wisconsin solution. We retrospectively analyzed 190 OLTs performed between September 1997 and July 2002 with regard to ITBLs. One hundre…
Optimizing endovascular stroke treatment: removing the microcatheter before clot retrieval with stent-retrievers increases aspiration flow
2016
BackgroundFlow control during endovascular stroke treatment with stent-retrievers is crucial for successful revascularization. The standard technique recommended by stent-retriever manufacturers implies obstruction of the respective access catheter by the microcatheter, through which the stent-retriever is delivered. This, in turn, results in reduced aspiration during thrombectomy. In order to maximize aspiration, we fully retract the microcatheter out of the access catheter before thrombectomy—an approach we term the ‘bare wire thrombectomy’ (BWT) technique. We verified the improved throughput with systematic in vitro studies and assessed the clinical effectiveness and safety of this metho…
Four-phase rhinomanometry: a multicentric retrospective analysis of 36,563 clinical measurements
2015
Rhinomanometry can still be considered as the standard technique for the objective assessment of the ven- tilatory function of the nose. Reliable technical requirements are given by fast digital sensors and modern information technology. However, the xyimaging of the pressure-flow relation typically shows loops as a sign of hysteresis, with the need for resolution of the breath in four phases. The three pillars of 4-phase rhinomanometry (4PR) are the replacement of estimations by measurements, the introduc- tion of parameters related to the subjective sensing of obstruction, and the graphical information regarding the disturbed function of the nasal valve. In a meta-analysis of 36,563 clini…
Möglichkeiten der 16-Schicht-CT bei der linksventrikulären Funktionsbestimmung: Beurteilung zweier unterschiedlicher Software-Tools zur quantitativen…
2004
PURPOSE To determine global and regional left ventricular (LV) function from retrospectively gated multidetector row computed tomography (CT) by using two different semiautomated analysis tools and to correlate the results with those of magnetic resonance imaging (MRI). MATERIALS AND METHODS Nineteen patients (5 females, 14 males, mean age 69 years) underwent 16-slice spiral-CT (MS-CT) with standard technique without administration of beta-blockers for a decrease in the cardiac rate. Ten series of images were reconstructed at every 10 % of the RR-interval. With commercially available software capable of semiautomated contour detection, end-diastolic and end-systolic LV volumes (EDV and ESV)…
A Two-Stage Reconstruction of Microstructures with Arbitrarily Shaped Inclusions
2020
The main goal of our research is to develop an effective method with a wide range of applications for the statistical reconstruction of heterogeneous microstructures with compact inclusions of any shape, such as highly irregular grains. The devised approach uses multi-scale extended entropic descriptors (ED) that quantify the degree of spatial non-uniformity of configurations of finite-sized objects. This technique is an innovative development of previously elaborated entropy methods for statistical reconstruction. Here, we discuss the two-dimensional case, but this method can be generalized into three dimensions. At the first stage, the developed procedure creates a set of black synthetic …
Die bestimmung der molekulargewichtsverteilung von nichtkristallisierenden polymeren mit dem elektronenmikroskop. I. Präparationsmethoden und kontrol…
1970
Bei der elektronenmikroskopischen Abbildung von Einzelmolekulen treten eine Reihe von praparativen Schwierigkeiten auf, welche dazu gefuhrt haben, das man trotz zahlreicher Arbeiten diese Methode bisher noch nicht zu einem Standardverfahren entwickeln konnte. Ein Haupthindernis stellt das Auftreten von Artefakten dar, die den nichtkristallinen Polymermolekulen tauschend ahnlich sehen. Zur Erkennung und Vermeidung dieser „Scheinmolekule” ist es notwendig, quantitative Praparations- und Kontrollmethoden zu entwickeln. Es eignen sich zwei Verfahren: einmal die sogenannte Tropfenmethode und zum anderen die Gefriertrocknungsmethode. Mit Hilfe dieser Verfahren gelingt es, das Artefaktproblem zu l…
SIMPLE, SAFE AND EASY TECHNIQUE TO ENSURE THE CORRECT LENGTH OF ARTIFICIAL CHORDAE IN MITRAL VALVE REPAIR.
2007
Replacement of diseased chordae with Gore-Tex sutures (W. L. Gore & Assoc, Flagstaff, AZ) in patients with degenerative mitral valve insufficiency has become a standard technique used by surgeons in mitral valve repair with good long-term results. Nevertheless, determining the correct length of the artificial chordae has remained problematic. Although various procedures have been previously published, in this article we describe our approach used to achieve an accurate chordal height adjustment.
A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm
2013
We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation. © Turkish Society of Radiology 2012.
Innovative fully robotic 4-arm Ivor Lewis esophagectomy for esophageal cancer (RAMIE4).
2019
Nowadays robotic surgery is established for abdominal and thoracic surgery. It has been shown that complex procedures are feasible using robotic systems, e.g., da Vinci Xi, with a huge benefit in precision. Different techniques for esophageal cancer surgery are reported; however, only a few robotic and partial robotic procedures are described. Therefore, a fully robotic (abdominal and thoracic) Ivor Lewis esophageal resection using four robotic arms-RAMIE4-the standard technique used for lower esophageal cancer, is presented in this paper. The technique shown in the video was performed successfully in 100 cases in 24 months. The reconstruction is performed with a gastric conduit pull-up and…